Gamma-Ray Crawler / Item No:ENK-GRC-229

 

Pipe Welding Inspection 2003

This equipment carries out radiographic inspection for the welding part as means to inspect normal or abnormal status of the welding part in the construction work of all types of pipeline (gas pipe, oil pipe, water pipe, etc).The RIC-2003 Radiographic Inspection Crawler is equipment automatically performing radiographic inspection and can accurately stop on the welding line while traveling inside of the pipe. This equipment permits to take a radiographic photograph with good quality on the film attached to the outside of the pipe by accurately disclosing accurate quantity of radioactive rays.

 

Features;

·          The RIC-2003 is a radiographic inspection equipment for the pipe welding part that automatically handles a series of work if pressing the start button after placing it at the pipe inlet and entering work conditions

·          This equipment is easy to operation and has excellent recognition capability since it displays operation status with the VFD

·          This equipment automatically calculates disclosing time of the source depending on working conditions and automatically handles radioactive rays disclosure work to obtain uniform and accurate film quality

This equipment has equipment recovery function with excellent reliability to return to the pipe inlet irrespective of programs after some time (about  1minute) if control error occurs for some reasons during work within the pipe, especially even if the power is cut off due to the fuse blown out or if abnormality occurs at the electronic circuits of equipment.

·          This equipment generates automatic warning sounds in disclosure to radioactive rays, and has excellent safety since it automatically try to repeatedly introduce a ray source while  increasing power several times even when there are obstacle factors such as mechanical hanging and when drawing the ray source again into the source container after disclosure and photo  graphic work

·          This equipment accurately detects movement of the source wire   and accurately controls for the ray source to return to the original position depending on understanding position of the ray source even when error occurs in the course

·          This equipment can maintain setup of use environment since data are saved as they are even if power turns off, and memorize the previous work environment even if power turns off and then on due to vibration or shock of equipment during travel

·          This equipment has no concern it may overturn internally when passing through the bend of a pipe(more than (f28�and less than 45°) since wheels for driving the main body is of structure * (patented) rolling to the left or right

·          This equipment attaches a water sensor to determine that water is filled within the pipe if using equipment in the rainy season and prevents failure by preventing submersion of equipment by * which filled water is returned out

·          This equipment is designed to be easy for A/S in failure and so has excellent A/S performance in occurrence of problems

·         

This equipment is made of light and solid material and structure

Classification

Specification

Application Tube Diameter

18�~ 50�/span>

Max. traveling distance

One-way :  1~999M

Double-way :  1~999M  Frequent travel

Curve tube passage

3DR 45o, f28�or more

Platform capacity

10 o slope degree

 

 

 

 

 

C

O

N

T

R

O

L

 

Control method

Self-program type, input before travel

Power used

DC 24V, 14AH

Calculation of radioactive ray disclosure

Automatic operation process by program

Photographing work

Automatic disclosure by positioner at standstill

Low Battery

detection function

Detection of low Battery. During progression: Automatic retract

Detection of low Battery. at start: Reject of departure

Submersion prevention

Water detection at bottom of main body: Refusal of forwarding, returning to original position

Failure diagnosis

Display of failure cause in failure of main parts

Returning to original position

Stop after returning to the starting point

Emergent

Returning

Emergent returning in failure of main parts

Encountering to obstacles

Automatic returning in encountering to obstacles

Drive speed

25M / Min

 

Dimmension

Size

1,000(L) x 460(W) x 500(H) : Based on 30�

 

Weight

1) 660 TANK :  22.5Kg

2) BATTERY :  12.8Kg

3)  Main Body   :  43.5Kg (based on 30�)

Positioner

Cs-137 / 30~50mCi

Battery charger

AC220V, 50/60Hz input / DC24V charging

 

         
Ultrasonik Muayene
Ultrasonik Muayene
Ultrasonik Muayene
   
enkom        

 


 
Bize Ulaşın
Adres : Kuzey Sahil Yolu Lodos Sok.No:9 Güzelyalı-Pendik/İstanbul
Telefon : +90 216 494 12 32 -   493 25 03 - 493 99 77
Faks : +90 216 493 99 81
E-mail : enkon@enkon.com.tr
 
Ürünlerimiz
Radyografik Muayene
Ultrasonik Muayene
Manyetik Muayene
Penetrant Muayene
Alloy Analyzer
Sertlik Ölçme
Diğer
 
foto galeri
 
AnasayfaKurumsalHizmetlerimiz Ekipmanlar Referanslarmz letiim