Anasayfa İletişim Site Haritası
TR EN  
 
 
Kurumsal   Hizmetler     Ürünler   Projeler   Temsilcilikler   Referanslar
     
Radyografik Muayene

Sources & Source Holders

Source holders offered by Hojin include a comprehensive choice of designs which match original equipment manufacturer specifications and are fully compatible with most current makes of gamma radiography projectors.

Selenium-75;

Selenium-75 sources are available in cylindrical and quasi-spherical focals,permitting shorter SFDs and great sensivity on fixed geometries.

Iridium-192;

Iridium-192 sources are constructed using iridium metal discs or pellets confined within welded stainless stell capsule.

Cobalt-60;

Cobalt-60 sources are constructed using compression fused cobalt metal pellets confined within welded titanium and stainless stell capsule.

Ytterbium-169;

Ytterbium-169 sources are available in spherical and right circular cylinder focals,housed in a welded titanium alloy capsule.

Iridium-192 source order item numbers;

-20 Ci / Item No:ENK-IRS-023

-30 Ci / Item No:ENK-IRS-024

-50 Ci / Item No:ENK-IRS-025

-70 Ci / Item No:ENK-IRS-026

-80 Ci / Item No:ENK-IRS-027

-100 Ci / Item No:ENK-IRS-028

Selenium-75 source order item numbers;

-50 Ci / Item No:ENK-SES-029

-80 Ci / Item No:ENK-SES-030

Co-60 source order item numbers;

-10 Ci / Item No:ENK-COS-031

-20 Ci / Item No:ENK-COS-032
-30 Ci / Item No:ENK-COS033
-50 Ci / Item No:ENK-COS-034
-100 Ci / Item No:ENK-COS-035
Ir-192 Source Holder for Sentinel and Tech-ops Projector / Item No:ENK-ISHST036
Ir-192 Source Holder for Gammamat Projector / Item No:ENK-IRSHG-037

         
enkom radyografik
enkom radyografik
enkom radyografik
enkom radyografik
 
enkom        
 

 


Remote Handling Tongs

Radiation Safety Remote Handling Tongs
�1,2 m (Al)
�Emergency source retrieval
�Maximizes distance between operator and source
�Used for handling detached gamma sources
Item No:ENK-RHT-121

Lead Apron �Size : 95cm
�Lead equivalent : 0.5mm(Lead)
Item No:ENK-LA-122

Lead Glove �Size : 335cm
�Lead equivalent : 0.3mm(Lead)
Item No:ENK-LGL-123

Lead Goggle

Item No:ENK-LGO-124

Warning Light
�Warning light LA-2 / Item No:ENK-LGO-125
�Warning light A100 / Item No:ENK-LGO-126
�Radiation hazard sigh �custom-made

Lead Block
�HT. HM. HB
�HCT, HCM, HCB
Item No:ENK-LBL-127

Lead Container
�R.I. storage container
�R.I. delivery container
�R.I. disposal container
Item No:ENK-LC-128

Radiation cutting equipment
Custom-made
Item No:ENK-RCE-129

         
enkom radyografik
enkom radyografik
     
enkom

Gamma-Ray Projector
880 Series Source Projectors Model 880 series source projectors are used for industrial applications of gamma radiography to inspect materials and structures in thedensity range of approximately 2.71 g/cm3 through 8.53 g/cm3.
SENTINELTM Model 880 Delta, 880 Sigma and 880 Elite source projectors are portable, lightweight and compact industrial radiographic exposure devices.  The patented device body consists of a titanium ��tube and cast depleted uranium (DU) shield contained within a 300 series     stainless steel tube with stainless steel discs welded at each end forming a cylinder shaped housing.  The discs are recessed to provide protection for the rear mounted locking mechanism and front mounted outlet port.
The horizontally oriented design allows the locking mechanism, source assembly connector and outlet port to be easily operated, simplifying connection of source guide tubes and remote controls.

 

Technical Spesifications

Model Seriesenkom radyografik

880 Delta,880 Sigma and 880 Elite.

Primary Application

Industrial Gamma Radiography.

Dimensions (all models)         Weight of exposure device

Length 13.3in (33.8cm).          Delta 52lb (23.6kg)

Width  7.5in (19.1cm)           Sigma 52lb (23.6kg)

Height  9in (22.9cm)            Elite 42lb (19.0kg)

Activity of depleted Uranium shield

Delta 5.4mCi (200MBq),Sigma 5.4mCi (200MBq),Elite 3.8mCi (141MBq).

Certification

Type B(U) package,USDOT Certification Number USA/9296/B(U)-96.

Accreditation

Sentinel 880 Delta,Sigma and Elite models are designed,tested and manufactured to meet the requirements of ANSI N432-1980,ISO 3999-1 2000E,IAEA TS-R-1 (1996),USNRC 10CFR34,10CFR71 and 49CFR173. Additionally,the exposure devices are designed,manufacturer and serviced under a QA program that has been accredited to ISO 9001 (2000) and aproved in accordance with USNRC 10 CFR71�ubpart H.The QA program also includes the reporting requirements of USNRC 10CFR21 for supplies of source and byproduct materials.

Construction

Exposure device     Depleted Uranium (DU) shield encased within a welded tubular stainless stell   shell with stainless steel end plates.Interior void space filled with rigid   polyurethane foam.

Removable Jacket   One �iece,high impact resistant,plastic jacket incorporating a carrying handle  and base

Materials

Titanium ��tube,DU shield,300 series stainless steel tubular shell and plates, aluminum, brass, tungsten and polyurethane.

Maximum capacities

Delta 150Ci (5.55TBq),Sigma 150Ci (5.55TBq),Elite 50Ci (1.85TBq) of Ir-192.

Source assembly and authorized contents

USNRC Model Number: A424-9 source assembly with a doubly encapsulated Ir-192 sealed source.The IAEA/USDOT Special Form Certificate number is USA/0335/S.In addition,the following isotopes may also be utilized in the 880 series exposure devices.

Isotope                 Ytterbium-169        Selenium-75        Iridium-192        Cobalt-60   

Assembly         Model number             918                  A-424-25W         A-424-9            A-424-19

Gamma

Energy range   8-308keV            66-401keV          206-612keV        1.17-1.33keV      

Half Life    32 days              120 days            74 days            5.27 years

Approximate steel

Working thickness 2-20mm              3-29mm            12-63mm           50-150mm

Device/source

Maximum capacity

880 Delta       20Ci   0.74TBq       80Ci   3.00TBq    150Ci   5.55TBq    65mCi   2.40GBq

880 Sigma     20Ci   0.74TBq       80Ci   3.00TBq    150Ci   4.81TBq    25mCi   925MBq

880 Elite 20Ci   0.74TBq       80Ci   3.00TBq     50Ci   4.81TBq     25mCi   925MBq

Controls and guide tubes

Compatible with standard (660 type) remote controls and source guide tubes.

Inspection requriments

Daily pre-operational inpection for obvious damage to the system.

Maintenance requirements

Most national regulations require inspection and maintenance of the system at quarterly intervals.The complete annual servicing ensures the integrity of the system.

Shorter frequencies of inspection and maintenance are required when the system is operated under severe operating environments. In some cases,the system should be serviced immediately after certain jobs in severe environmental working conditions.

Operating temperature range

-40ºF to 300ºF (-40ºC to 149ºC)

680B Projector with OPL                
The SENTINELTM Model 680B source projector combines the penetrating radiation of Cobalt-60 with
the mobility provided by the use of depleted uranium shielding. It is designed for the radiography of steel
from 1 in to 7 in (25 mm to 175 mm) thick and light alloys 3 in to 15 in (75 mm to 375 mm) thick. All components have been developed to provide safe, reliable service and long life under the harsh conditions of industrial use. The durable case is designed to ease rigging operations.
A lock is incorporated to prevent use by unauthorized personnel. The source cannot be projected until the control cable is correctly connected. The projector can not be locked or the control cable disconnected until the source is safely stored. Projectors with codes that include the letter A or B are fitted with the unique Posilock device which automatically secures the source assembly in the stored position on retraction. Remote controls allow the operator to control the source at a distances of 35 ft (10.7 m) or 50 ft (15.2 m).When the source is in the exposure position the control can be a total distance of 46 ft (14 m) using 25 ft controls, 63 ft (19.2 m) using 35 ft controls, or 99 ft (30 m) using 50 ft controls.

Exposure Device
Dimensions;
�Length: 21 in (53cm)
�Width: 14-3/4 in (38cm)
�Height: 12 in (30cm)
�Mass:465 lb (211kg)

Source Capasity: 110 Ci (4.07TBq) ,Cobalt-60

Shielding:
�Material: Depleted Uranium
�Mass: 295 lb (130kg)


Radiation Safety Surveymeter

Radiation Safety
Surveymeter

The RSM series is newly developed system for user� comfortableness and easy handling with required accuracy.

RSM Series supply in 3 type of energy compensated GM-tube, for low radiation measuenkom radyografikrement RSM-100E, for high radiation measurement RSM-200E and wide range measurement (from background level to max.1Sv/h) RSM-300E.

Display of the units designed for wide (60×50mm) and clear view.
20segments analog bar-graph displayed with digital result simultaneously. it provide full information such as surveying results, units, tolerance of the statistics status of overflow from reference level, status of battery, message of sufficient measuring time, with characteristic symbol and digits.
Switch buttons are located for one hand operation
Shock resistant ABS plastic case and stainless battery cover will provide durable work conditions in field.

RSM Series has been confirmed that satisfied from accuracy, angular dependence test, energy dependence test, environmental temperature and humidity test, electrostatic discharge test, frequency test of power, resistant test in electromagnetic field, resistant test in emission of radio electronic wave field, mechanical shock test, vibration test by KAERI(Korea Atomic Energy Research Institute), KTL(Korea Testing Laboratory) and ILJIN Radiation Engineering Co., Ltd., International certified calibration institute (ISO/IEC17025, ISO9002)

Main Function; �Korean/English version
�20 Segment Bar-graph
�Selection switch of the unit(Sv/h, R/h)
�Back Light
�Measurement result
�Battery status bar-graph
�4 Digital LCD
�Measurement Range(~20m Sv/h)
�Buzzle function(audible effect)
�Calibration factor(by calibration mode)
�Freeze the result for notice
�Statistic tolerance displayed relative value(%)

End User Reference �Nuclean power plan
�Industrial
�Hospital
�Institute
�Army
�Fire station
�Police station

Item No:ENK-RSM100E-114 (RSM-100E Model-Low Range)
Item No:ENK-RSM200E-115 (RSM-200E Model-High Range)
Item No:ENK-RSM300E-116 (RSM-300E Model-Wide Range)
                                                                    

TECHNICAL SPESIFICATIONS

Physical
Characteristic

Size
Case Material
Control Panel
Weight

86(W)×171(L)×47IT)mm

ABS Tempered Plastic
Membrane switch panel
410g(without Battery)

Output
Form

Display
Language
UnitDiapaly. Digit
Statistic Disp.
Back light type

LCD(60×50mm)

English
Sv/h, R/h
4 Digit/20 segment Bar-gragh
4 Digit( Uit:%)
EL Type

Response of
Radiation

 

Measur. Obj.
Detector type
Measur. Range


Accuracy*
Energy Dep*
Angular Dep*
Response Time

 

Gamma, x-ray
Energy compensated GM-Tube
RSM-100:B.G Level ~ 20 mSv/h
RSM-300:B.G Level ~ 1 Sv/h
? ±10%
? ±20%, 60keV ~ 1.2 MeV
? ±20%,(within ± 80°)
Auto adh./fast react, fast collect.

algorit

Response of
Interference

Electrostatic discharge test.
Frequency test of power
In Electromagnetic field.
Emission of radio electronic
wave filed.

 

IEC 61000-4-2 satisfied
IEC 61000-4-8 satisfied
IEC 61000-4-3 satisfied

Environmental

Acc.Temperature*
Acc.HuMidity*
Physical Shock Vibration*

-10? ~ 50? (15 ~ 22?)
40%~95%/22?
11ms, 50g satisfied
10 ~ 33Hz, 2G satisfied

Power supply
Duration time*

2x, 1.5V¨C¨size Alkaline
> 200 hr

Internal function

POST function
Display of insufficient measurement time
Display of over and under from ref. Value.
Battery status bar-gragh
Result freeze function.
Cal. Factor Adjust. In digital methode


*Satisfiled, Required ANSI N42. 17A


Radiation Safety Personel Dozimetry

Radiation Safety
Personel Dozimetry

Atomtex Personal Dosimeter / Digital;

Easy to operate, pocket-sized microprocessor instruments with high accuracy and reliability. Together with the reader connected to PC it can be a part of automated monitoring system of staff dose burden.
Features;
�Simultaneous wide-range gamma radiation dose and dose rate measuring
�Proof aginst impacts and vibrations, dust and water, electromegnetic-resistant
�Continuous self-testing of detector and cells discharge
�Audible and visual alarm
�Stand-alone or system application
�Pocket-sized and light weight
�Pulsed x-ray radiation alarming mode, pulse duration > 10 ns

Application;
�Nuclear industry
�Nuclear medicine
�Radiology
�NDT
�Emergency
�Civil aviation
�Scientific research
�Population dose burden monitoring

The dosimeters are intended to measure personal equivalent x-ray and gamma radiation dose and dose rate in the energy range from 50 keV to 1.5 MeV. The detector is GM-tube with the energy compensative filter. Microprocessor processing and proper background detection ensure high accuracy of dose measurement within the wide dose rate measuring range. The microprocessor controls operation modes over, calculates, outputs data on a backlit LCD and performs self-testing. The nonvolatile memory keeps the accumulated dose and its accumulation history when the dosimeter is off. The dosimeter is calibrated on a water phantom of 30 x 30 x 15 cm. The dosimeter is designed to be carried in a breast pocket. It complies with ISO4037-3 International standard requirements.
The dosimeter can operate singly or in a dosimetry control system: dosimeter - reader - PC. The dosimeter connects to the reader via IR channel, and the reader connects to PC via RS232. The dosimeter software is intended to:

- Read/setup personal and serial dosimeter numbers;
- Change dose and dose rate thresholds;
- Disable/enable to change dosimeter thresholds by the dosimeter button;
- Change the dose accumulation interval in the range from 1 to 255 min and evaluate accumulated dose for each time interval within a work shift;
- Save automatically up to 800 dose values in the nonvolatile memory accumulated for the selected accumulation interval;
- Reset accumulated dose;
- Disable/enable to reset accumulated dose by the dosimeter button;
- Save automatically data in the data base and print them.
The operation modes are "Dose ", "Dose rate ", "Economical", "Menu", "Reset dose", "Dose threshold", "Dose rate threshold" and "Data exchange with PC".

Item No:ENK-PDD-117

TECHNICAL  SPESIFICATIONS

Measuring range

 

dose equivalent (in increment of 0.1 µSv)

 

AT2503, AT2503A

1 µSv - 10 Sv

dose equivalent rate

 

AT2503

0.1 µSv/h - 0.5 Sv/h

AT2503A

0.1 µSv/h - 0.1 Sv/h

Energy range

50 keV - 1.5 MeV

Intrinsic dose measurement error

± 15 %

Calibration error on 137Cs

± 5 %

Intrinsic dose rate measurement error

 

in the range from 0.1 to 1 µSv/h

± 25 %

more than 1 µSv/h

± 15 %

Energy sensitivity response
in the range from 50 keV to 1.5 MeV

± 30 %

Audible and visual alarm at dose and dose rate measuring range or dose and dose rate threshold exceeding; detector failure; cells discharge

 

Alarm thresholds (independent)

 

dose: 30 µSv, 200 µSv, 1 mSv, 4.2 mSv, 12.5 mSv, 50 mSv, 100 mSv, 1 Sv

 

dose rate: 0.6 µSv/h, 3 µSv/h, 30 µSv/h, 300 µSv/h, 3 mSv/h, 30 mSv/h, 300 mSv/h, 500 mSv/h

 

customized thresholds

 

Anisotropy within ±75°

 

for 137Cs and 60Co

± 20 %

for 241Am

± 50%

Response time to dose rate change when dose rate > 10 µSv/h

5 s

Radiation overload

 

AT2503

up to 5 Sv/h

AT2503A

up to 1 Sv/h

Operating conditions

 

operating temperature range

-10? - + 40?

relative humidity at + 40? ?

up to 98 %

shock-proof (to fall from 1.5 m)

 

Operation mode setup time

1 min

Protection class

IP54 

Power requirements - 3 cells, type

SR44, V357, LR44, A76

Continuous operation time from one cells set
when dose rate < 1 µSv/h in economical mode (the backlighting is off)

5000 h

Electromagnetic compatibility

 

CEI/IEC 61000-4-2:1995)

 

IEC 61000-4-3:2002)

 

Dimensions

 

dosimeter

85?46?16 mm

reader

90?66?28 mm

Weight

 

dosimeter

70 g

reader

300 g

Complete set: personal dosimeter, cells, chain with a clamp, plastic boxes for easy decontamination, Manual and package. The reader and applied software and AT2503 and AT2503A modifications with the operating temperature range from-30 to +600? and the optional pulsed x-ray radiation alarming mode are supplied on additional order.
The personal dosimeters AT2503 and AT2503A have pattern approval certificates of Republic of Belarus, Russian Federation, Ukraine, Kazakhstan and Lithuania.
They comply with IEC 61283 International standard requirements. They also conform with the 89/33/EEC Directive complying with EN 55022 B:1998 and EN 55024 B: 1998 stansdard requirements.
         
enkom radyografik
enkom radyografik
     
enkom

Radiation Alarm Monitor & Dosimeter

Radiation Safety
Radiation Alarm Monitor / Catch-1;

Features and Applications;

Personal radiation alarm monitor is very compact and light weight unit for operator who works in range of radiation occurrence such as nuclear plant, hospital, university, and industrial field. Alarm sound over 75dB and also red LED display signals the exposure of X-ray, ?-ray, ß-ray immediately.
Catch-1 is very light and compact (49x72.5x16mm/55g) size and can be attached to the belt, shirt pocket, apron, etc with the very rugged clip.
Power supplied by only one 1.5V battery(AAA size) and life time is about 5,000 hours.

TECHNICAL SPECIFICATIONS

  RADIATION DETECTED

  X-RAY AND GAMMA, HARD BETA

  ENERGY RANGE

  30KEV TO 1.25 MEV.

  DETECTOR

  G. M. TUBE

  SIGNAL

  AUDIBLE AND LED: INDECATOR LIGHT

  SOUND LEVEL

  75dB

  PULSE DURATION

  100ms

  PULSE FREQUENCY

  2,500 ~ 2,600Hz

  ON-OFF SWITCH

  NONE: IN CONSTANT STAND-BY OPERATION MODE

  SENSITIVITY
  (TYPICAL FOR CESIUM-137)

  BACKGROUND: 1BLEEP PER 10 ~ 20min
  1mR/h: 3 BLEEPS/min
  10mR/h: 30 BLEEPS/min 1R/h AND UP CONTINUOUS TONE

  OPERATING TEMPERATURE
  RANGE

  -15°C ~ 50°C

  RELATIVE HUMIDITY

  10% ~ 80%

  WATER

  RESISTANT

  BATTERY TYPE

  AAA TYPE 1.5V ONE TYPE

  TYPIACAL BATTERY LIFE

  MINIMUM 6 MONTHS WITH CONTINUOUS BACKGROUND
  RADIATON FIELD: EASILY REPLACED

  SIZE

  72.5 x 16 x 49mm (2.85 x 0.63 x1.9in)

  WEIGHT

  APPROX. 55 GRAMS(1.94OZ INCLUDING BATTERIES

  CASE

  MATERIAL ABS

Item No:ENK-RAM-118
Radiation Safety
Pen Dosimeter

Applications;
�Portable instrument specially designed to measure your body"s total accumulated dose.
�Pen size
�A rugged pocket clip enables the device to be secured in a shirt pocket or elsewhere on the user"s garments.
�Simple to use
�Direct-reading of radiation exposure and dose
Spesifications;
�Direct gamma and x-ray dosimeter
�0-200 mR Measuring range
�Temperature Range:  -20º to 50º C
�4.5 in (L) x 0.6 in (D)
       (11.43 cm (L) x 1.52 cm (D))

Item No:ENK-PD-119

Dosimeter Charger

Dosimeter charger display the charging condition and easy to use and light weight.
Supplied power is only one 1.5V battery and 1000 times over charging is possible

Spesifications;
�Direct reading dosimeter charger
�Compatible with all dosimeters
�Activated by contact with dosimeter
�3.4 in (H) x 3.6 in (W) x 4.6 in (L)
(8.64 cm (H) x 9.14 cm (W) x 11.68 cm (L))


Item No:ENK-DC-120

         
enkom radyografik
enkom radyografik
enkom radyografik
enkom radyografik
 
enkom  

Penatremeter & Step Wedges
       

F 04

F 08

Item No:ENK-WPKSF-080

Item No:ENK-WPKSF-081

Item No:ENK-WPKSF-082

Stell

F 02

F 04

F 08

Item No:ENK-WPJISF-089

Item No:ENK-WPJISF-090

Item No:ENK-WPJISF-091

Stell

S 02

S 04

S 08

Item No:ENK-WPKSS-083

Item No:ENK-WPKSS-084

Item No:ENK-WPKSS-085

Stainless

S 02

S 04

S 08

Item No:ENK-WPJISS-092

Item No:ENK-WPJISS-093

Item No:ENK-WPJISS-094

Stainless

A 02

A 04

A 08

Item No:ENK-WPKSA-086

Item No:ENK-WPKSA-087

Item No:ENK-WPKSA-088

Aluminum

A 02

A 04

A 08

Item No:ENK-WPJISA-095

Item No:ENK-WPJISA-096

Item No:ENK-WPJISA-097

Aluminum

En Type; �13/Fe, Cu, Al(2, 5 �10mm) / Item No:ENK-ENP13-098
�10/Fe, Cu, Al(5 �20mm) / Item No:ENK-ENP10-099
�6/Fe, Cu, Al(12.5 �50mm) / Item No:ENK-ENP6-100
�1/Fe, Cu,Al(40 �160mm) / Item No:ENK-ENP1-101

Hole Type; �ASME
SET��/ 5, 7, 10, 12, 15, 17, 20, 25, 30, 35, 40, 45, 50 / Item No:ENK-ASMEPA-102
SET��/ 60, 80, 100, 120, 160, 200 /              Item No:ENK-ASMEPA-103
�ASTM / 5-160 / Item No:ENK-ASMTP-104
�MIL STD-453 / .25-8.0 / Item No:ENK-MILP-105
�AFNOR (HA,HB,C,H3) / Item No:ENK-AFNP-106

#Material selection(When you purchase / Steel, AL, S/S, Cu, etc)

Step Wedges �4Step / Stell, Al, S/S / Item No:ENK-SW-107
�8Step / Stell, Al, S/S / Item No:ENK-SW-108
�16Step / Stell, Al, S/S / Item No:ENK-SW-109
Step wedges are used for the calibration of X-ray machines and evaluation of techniques.

Contrast Meter �F1 (Steel) / Item No:ENK-CM-110
�F2 (Steel) / Item No:ENK-CM-111
�D1, D2, D3, D4 (Aluminium) / Item No:ENK-CM-112
�15 type, 20 type, 25 type / Item No:ENK-CM-113

         
enkom radyografik
enkom radyografik
enkom radyografik
   
enkom  

Exposure Accessories

Lead Mark & Lead Mark Case
Lead Mark;
�R-1 / Item No:ENK-LM1-059
�R-30 / Item No:ENK-LM30-060
�R-50 / Item No:ENK-LM50-061
�R-100 / Item No:ENK-LM100-062
Configuration of R-30;
1 - 0 : 30marks each
A - Z : 30marks each
Lead Mark Case;
Lead Mark Case / Item No:ENK-LMC-063

Lead Screen
Lead Alloy Intensifying Screens;
�Reduced Scattered Radiation
�Intensifies Image
�Available in rolls and all popular sheet size
Size;
�10 cm X 12 cm / Item No:ENK-LAS-064
�10 cm X 16 cm / Item No:ENK-LAS-065
�10 cm X 24 cm / Item No:ENK-LAS-066
�10 cm X 48 cm / Item No:ENK-LAS-067

Thickness: 0.125mm, 0.25mm, 1.0mm

Fluorescent Screen;
�Reduced Scattered Radiation
�Intensifies Image
�Available in rolls and all popular sheet size
�4 times better sensitivity than lead alloy intensifying screen
Size;
�10 cm X 12 cm / Item No:ENK-LFS-068
�10 cm X 16 cm / Item No:ENK-LFS-069
�10 cm X 24 cm / Item No:ENK-LFS-070
�10 cm X 48 cm / Item No:ENK-LFS-071

Film Casette
Plastic Type Size;
�10 cm X 12 cm / Item No:ENK-FCP-072
�10 cm X 16 cm / Item No:ENK-FCP-073
�10 cm X 24 cm / Item No:ENK-FCP-074
�10 cm X 48 cm / Item No:ENK-FCP-075

Magnetic Chuck
�MD �L type / Item No:ENK-MC-076
�MD �S type / Item No:ENK-MC-077
�MAG �S type / Item No:ENK-MC-078
�NFC� type(for non ferromagnetic) / Item No:ENK-MC-079
Holding force to attach any size film cassette to a magnetic steel surface.

         
enkom radyografik
enkom radyografik
enkom radyografik
enkom radyografik
 
enkom  

Darkrooms & Equipments

Film Iluminators �Power: 1 ? 220V 50/60Hz  1.52A 350W
�Material: SS41 Plate
�Fluorescent Lamp: U-Type 55W 6EA
�Cooling Fan: 230V 16/14W 
�Size: 605(L) X 200 (W) X 195 (H)�Unit = mm
�Illimunation View Face: Fluorescent Lamp 130.000 �150.000 Lux
�Electronic Ballast For Fluorescent Lamp 220V 50/60Hz 52W
�Weight:About 10 kg
�Switch:On/Off foot switch
Stainless Steel Item No:ENK-FI-042
Carbon Steel Item No:ENK-FI-043

Darkroom Safe Light �15 watt Lamp
�Can be mounted on a wall or hung from a ceiling
�8 in (W) X 10 in (H)
(20 cm (W) X 25 cm (H))
Item No:ENK-DSF-044

Film Hanger �10 cm X 12 cm / Item No:ENK-FH-045
�10 cm X 16 cm / Item No:ENK-FH-046
�10 cm X 24 cm / Item No:ENK-FH-047
�10 cm X 48 cm / Item No:ENK-FH-048

Darkroom Accessories Darkroom ventilator / Item No:ENK-DADV-049
Darkroom timer / Item No:ENK-DADT-050
Thermometer Item No:ENK-DATH-051
Film Storage Box / Item No:ENK-DASB-052
Film Cutter / Item No:ENK-DAFC-053

Film DensitometerPDA-100 Digital Densitometer ;
�Light Weight,Portable
�Power: AA Battery
�Accuracy: ±0.03D
�Range: 0 �4.0D
�Size : 160 x 65 x 30mm 400g
Item No:ENK-FD-054
X-Rite 301 Digital Densitometer; 
�Power: AC220V/60Hz
�Accuracy: ±0.02D / 1.2mm �3mm
�Range: 0 �5.0D
�Size : 260.4 x 381 x 133.4mm
Item No:ENK-FD-055
X-Rite 331 Digital Densitometer; 
Item No:ENK-FD-056

Reference Films �ASTM/E155,E186,E192,E272,E280 ,E310,E242, E390, E446
�IIW / Al. Steel
Item No:ENK-RF-057

Film Density StripItem No:ENK-FDS-058

         
enkom radyografik
enkom radyografik
enkom radyografik
enkom radyografik
 
enkom  

Control Assemblies & Source Guide Tubes

Control AssembliesReel Control Assembly-KRC1;
Size:25 ft (7.5 m) / Item No:ENK-CA-005
35 ft (10.5 m) / Item No:ENK-CA-006
50 ft (15 m) / Item No:ENK-CA-007
-Pistol Control Assembly-KRC2;
Size:25 ft (7.5 m)/ Item No:ENK-CA-008
35 ft (10.5 m) / Item No:ENK-CA-009
50 ft (15 m) / Item No:ENK-CA-010
-Pistol Grip Control-KRC2 / Item No:ENK-CA-011
-Pistol Grip Control-KRC1 / Item No:ENK-CO-012
*Customs length are available for reel control assembly and pistol control assembly
Control Assembly Accessories;
1-Safety Connector / Item No:ENK-CA-013
2-Control Cable Adaptor / Item No:ENK-CA-014
3-Crank Arm Assembly / Item No:ENK-CA-015
Source Guide TubesSource Guide Tube with Fixed Stop;
Size:7 ft (2.1 m) / Item No:ENK-SG-016
-Source Guide Tube Extension;
Size:7 ft (2.1 m) / Item No:ENK-SG-017
*Customs length are available for source guide tube with fixed stop and source guide tube extension
-Source Guide Accessories;
1-Removable source stop for source guide tube /
Item No:ENK-SG-018
2-Connector for source guide tube /
Item No:ENK-SG-019 
3-Fixed source stop for source guide tube /
Item No:ENK-SG-020
4- Connector for source guide tube extension /
Item No:ENK-SG-021
5- Connector for source guide tube extension /
Item No:ENK-SG-022

enkom radyografik
enkom radyografik
enkom radyografik
enkom radyografik
enkom radyografik
enkom  

Collimators & Real Time Imaging System

Gamma-Ray Collimators

Collimators contain and direct the beam of radiation during exposure.A wide range of collimators have been developed to meet the variety of applications and techniques used.

-Collimator TSC-19 (90º),TSC-19 (120º), TSC-19P (360º);

 

TSC-19 (90º)

TSC-19 (120º)

TSC-19P (360º)

Shielding Material

Tungsten

Tungsten

Tungsten

Diameter

30 mm

30 mm

32 mm

Length

54 mm

54 mm

58 mm

Weight

390 gr

400 gr

360 gr

Beam Size

90 Conical Side Throw

120 Conical Side Throw

360º Panoramic

Attenuation

Ir-192:1.0x10-1 , Co-60:3.8 x 10-1  

Ir-192:1.0x10-1 , Co-60:3.8 x 10-1  

Ir-192:1.0x10-1 , Co-60:3.8 x 10-1  

Item No

ENK-CO-038

ENK-CO-039

ENK-CO-040


Real time Imaging System

Imaging scope specifications
X-ray source : Gadolinium �153 isotope
Isotope Half life : 242days
Principle X-ray energies : 44keV and 100KeV
Power source : Two 1.5 volt ��size alkaline batteries
Image resolution : Up to 5lp/mm
Weight : 4.3kg(9.5 lbs)
License requirements : A license to possess a radioactive isotope is normally needed.
We will assist you if required.
Item No:ENK-RI-041
         
enkom radyografik enkom radyografik enkom radyografik    
enkom        
 

 

 
Bize Ulaşın
Adres : Kuzey Sahil Yolu Lodos Sok.No:9 Güzelyalı-Pendik/İstanbul
Telefon : +90 216 494 12 32 -   493 25 03 - 493 99 77
Faks : +90 216 493 99 81
E-mail : enkon@enkon.com.tr
 
Ürünlerimiz
Radyografik Muayene
Ultrasonik Muayene
Manyetik Muayene
Penetrant Muayene
Alloy Analyzer
Sertlik Ölçme
Diğer
 
foto galeri
 