Radyografik Muayene |
|
Sources & Source Holders
|
|
Source holders offered by Hojin include a comprehensive choice of designs which match original equipment manufacturer specifications and are fully compatible with most current makes of gamma radiography projectors.
Selenium-75;
Selenium-75 sources are available in cylindrical and quasi-spherical focals,permitting shorter SFDs and great sensivity on fixed geometries.
Iridium-192;
Iridium-192 sources are constructed using iridium metal discs or pellets confined within welded stainless stell capsule.
Cobalt-60;
Cobalt-60 sources are constructed using compression fused cobalt metal pellets confined within welded titanium and stainless stell capsule.
Ytterbium-169;
Ytterbium-169 sources are available in spherical and right circular cylinder focals,housed in a welded titanium alloy capsule.
Iridium-192 source order item numbers;
-20 Ci / Item No:ENK-IRS-023
-30 Ci / Item No:ENK-IRS-024
-50 Ci / Item No:ENK-IRS-025
-70 Ci / Item No:ENK-IRS-026
-80 Ci / Item No:ENK-IRS-027
-100 Ci / Item No:ENK-IRS-028
Selenium-75 source order item numbers;
-50 Ci / Item No:ENK-SES-029
-80 Ci / Item No:ENK-SES-030
Co-60 source order item numbers;
-10 Ci / Item No:ENK-COS-031
-20 Ci / Item No:ENK-COS-032
-30 Ci / Item No:ENK-COS033
-50 Ci / Item No:ENK-COS-034
-100 Ci / Item No:ENK-COS-035
Ir-192 Source Holder for Sentinel and Tech-ops Projector / Item No:ENK-ISHST036
Ir-192 Source Holder for Gammamat Projector / Item No:ENK-IRSHG-037
|
|
|
|
|
|
|
Remote Handling Tongs
|
|
Radiation Safety Remote Handling Tongs
�1,2 m (Al)
�Emergency source retrieval
�Maximizes distance between operator and source
�Used for handling detached gamma sources
Item No:ENK-RHT-121
Lead Apron �Size : 95cm
�Lead equivalent : 0.5mm(Lead)
Item No:ENK-LA-122
Lead Glove �Size : 335cm
�Lead equivalent : 0.3mm(Lead)
Item No:ENK-LGL-123
Lead Goggle
Item No:ENK-LGO-124
Warning Light
�Warning light LA-2 / Item No:ENK-LGO-125
�Warning light A100 / Item No:ENK-LGO-126
�Radiation hazard sigh �custom-made
Lead Block
�HT. HM. HB
�HCT, HCM, HCB
Item No:ENK-LBL-127
Lead Container
�R.I. storage container
�R.I. delivery container
�R.I. disposal container
Item No:ENK-LC-128
Radiation cutting equipment
Custom-made
Item No:ENK-RCE-129
|
|
|
Gamma-Ray Projector
880 Series Source Projectors Model 880 series source projectors are used for industrial applications of gamma radiography to inspect materials and structures in thedensity range of approximately 2.71 g/cm3 through 8.53 g/cm3.
SENTINELTM Model 880 Delta, 880 Sigma and 880 Elite source projectors are portable, lightweight and compact industrial radiographic exposure devices. The patented device body consists of a titanium ��tube and cast depleted uranium (DU) shield contained within a 300 series stainless steel tube with stainless steel discs welded at each end forming a cylinder shaped housing. The discs are recessed to provide protection for the rear mounted locking mechanism and front mounted outlet port.
The horizontally oriented design allows the locking mechanism, source assembly connector and outlet port to be easily operated, simplifying connection of source guide tubes and remote controls.
|
Technical Spesifications
|
|
Model Series
880 Delta,880 Sigma and 880 Elite.
|
|
Primary Application
Industrial Gamma Radiography.
|
|
Dimensions (all models) Weight of exposure device
Length 13.3in (33.8cm). Delta 52lb (23.6kg)
Width 7.5in (19.1cm) Sigma 52lb (23.6kg)
Height 9in (22.9cm) Elite 42lb (19.0kg)
|
|
Activity of depleted Uranium shield
Delta 5.4mCi (200MBq),Sigma 5.4mCi (200MBq),Elite 3.8mCi (141MBq).
|
|
Certification
Type B(U) package,USDOT Certification Number USA/9296/B(U)-96.
|
|
Accreditation
Sentinel 880 Delta,Sigma and Elite models are designed,tested and manufactured to meet the requirements of ANSI N432-1980,ISO 3999-1 2000E,IAEA TS-R-1 (1996),USNRC 10CFR34,10CFR71 and 49CFR173. Additionally,the exposure devices are designed,manufacturer and serviced under a QA program that has been accredited to ISO 9001 (2000) and aproved in accordance with USNRC 10 CFR71�ubpart H.The QA program also includes the reporting requirements of USNRC 10CFR21 for supplies of source and byproduct materials.
|
|
Construction
Exposure device Depleted Uranium (DU) shield encased within a welded tubular stainless stell shell with stainless steel end plates.Interior void space filled with rigid polyurethane foam.
Removable Jacket One �iece,high impact resistant,plastic jacket incorporating a carrying handle and base
|
|
Materials
Titanium ��tube,DU shield,300 series stainless steel tubular shell and plates, aluminum, brass, tungsten and polyurethane.
|
|
Maximum capacities
Delta 150Ci (5.55TBq),Sigma 150Ci (5.55TBq),Elite 50Ci (1.85TBq) of Ir-192.
|
|
Source assembly and authorized contents
USNRC Model Number: A424-9 source assembly with a doubly encapsulated Ir-192 sealed source.The IAEA/USDOT Special Form Certificate number is USA/0335/S.In addition,the following isotopes may also be utilized in the 880 series exposure devices.
|
|
Isotope Ytterbium-169 Selenium-75 Iridium-192 Cobalt-60
|
|
Assembly Model number 918 A-424-25W A-424-9 A-424-19
|
|
Gamma
Energy range 8-308keV 66-401keV 206-612keV 1.17-1.33keV
|
|
Half Life 32 days 120 days 74 days 5.27 years
|
|
Approximate steel
Working thickness 2-20mm 3-29mm 12-63mm 50-150mm
|
|
Device/source
Maximum capacity
|
|
880 Delta 20Ci 0.74TBq 80Ci 3.00TBq 150Ci 5.55TBq 65mCi 2.40GBq
|
|
880 Sigma 20Ci 0.74TBq 80Ci 3.00TBq 150Ci 4.81TBq 25mCi 925MBq
|
|
880 Elite 20Ci 0.74TBq 80Ci 3.00TBq 50Ci 4.81TBq 25mCi 925MBq
|
|
Controls and guide tubes
Compatible with standard (660 type) remote controls and source guide tubes.
|
|
Inspection requriments
Daily pre-operational inpection for obvious damage to the system.
|
|
Maintenance requirements
Most national regulations require inspection and maintenance of the system at quarterly intervals.The complete annual servicing ensures the integrity of the system.
Shorter frequencies of inspection and maintenance are required when the system is operated under severe operating environments. In some cases,the system should be serviced immediately after certain jobs in severe environmental working conditions.
|
|
Operating temperature range
-40ºF to 300ºF (-40ºC to 149ºC)
|
680B Projector with OPL
The SENTINELTM Model 680B source projector combines the penetrating radiation of Cobalt-60 with
the mobility provided by the use of depleted uranium shielding. It is designed for the radiography of steel
from 1 in to 7 in (25 mm to 175 mm) thick and light alloys 3 in to 15 in (75 mm to 375 mm) thick. All components have been developed to provide safe, reliable service and long life under the harsh conditions of industrial use. The durable case is designed to ease rigging operations.
A lock is incorporated to prevent use by unauthorized personnel. The source cannot be projected until the control cable is correctly connected. The projector can not be locked or the control cable disconnected until the source is safely stored. Projectors with codes that include the letter A or B are fitted with the unique Posilock device which automatically secures the source assembly in the stored position on retraction. Remote controls allow the operator to control the source at a distances of 35 ft (10.7 m) or 50 ft (15.2 m).When the source is in the exposure position the control can be a total distance of 46 ft (14 m) using 25 ft controls, 63 ft (19.2 m) using 35 ft controls, or 99 ft (30 m) using 50 ft controls.
Exposure Device
Dimensions;
�Length: 21 in (53cm)
�Width: 14-3/4 in (38cm)
�Height: 12 in (30cm)
�Mass:465 lb (211kg)
Source Capasity: 110 Ci (4.07TBq) ,Cobalt-60
Shielding:
�Material: Depleted Uranium
�Mass: 295 lb (130kg)
Radiation Safety Surveymeter
Radiation Safety
Surveymeter
The RSM series is newly developed system for user� comfortableness and easy handling with required accuracy.
RSM Series supply in 3 type of energy compensated GM-tube, for low radiation measu rement RSM-100E, for high radiation measurement RSM-200E and wide range measurement (from background level to max.1Sv/h) RSM-300E.
Display of the units designed for wide (60×50mm) and clear view.
20segments analog bar-graph displayed with digital result simultaneously. it provide full information such as surveying results, units, tolerance of the statistics status of overflow from reference level, status of battery, message of sufficient measuring time, with characteristic symbol and digits.
Switch buttons are located for one hand operation
Shock resistant ABS plastic case and stainless battery cover will provide durable work conditions in field.
RSM Series has been confirmed that satisfied from accuracy, angular dependence test, energy dependence test, environmental temperature and humidity test, electrostatic discharge test, frequency test of power, resistant test in electromagnetic field, resistant test in emission of radio electronic wave field, mechanical shock test, vibration test by KAERI(Korea Atomic Energy Research Institute), KTL(Korea Testing Laboratory) and ILJIN Radiation Engineering Co., Ltd., International certified calibration institute (ISO/IEC17025, ISO9002)
Main Function; �Korean/English version
�20 Segment Bar-graph
�Selection switch of the unit(Sv/h, R/h)
�Back Light
�Measurement result
�Battery status bar-graph
�4 Digital LCD
�Measurement Range(~20m Sv/h)
�Buzzle function(audible effect)
�Calibration factor(by calibration mode)
�Freeze the result for notice
�Statistic tolerance displayed relative value(%)
End User Reference �Nuclean power plan
�Industrial
�Hospital
�Institute
�Army
�Fire station
�Police station
Item No:ENK-RSM100E-114 (RSM-100E Model-Low Range)
Item No:ENK-RSM200E-115 (RSM-200E Model-High Range)
Item No:ENK-RSM300E-116 (RSM-300E Model-Wide Range)
TECHNICAL SPESIFICATIONS
|
Physical
Characteristic
|
Size
Case Material
Control Panel
Weight
|
86(W)×171(L)×47IT)mm
ABS Tempered Plastic
Membrane switch panel
410g(without Battery)
|
|
Output
Form
|
Display
Language
UnitDiapaly. Digit
Statistic Disp.
Back light type
|
LCD(60×50mm)
English
Sv/h, R/h
4 Digit/20 segment Bar-gragh
4 Digit( Uit:%)
EL Type
|
|
Response of
Radiation
|
Measur. Obj.
Detector type
Measur. Range
Accuracy*
Energy Dep*
Angular Dep*
Response Time
|
Gamma, x-ray
Energy compensated GM-Tube
RSM-100:B.G Level ~ 20 mSv/h
RSM-300:B.G Level ~ 1 Sv/h
? ±10%
? ±20%, 60keV ~ 1.2 MeV
? ±20%,(within ± 80°)
Auto adh./fast react, fast collect.
algorit
|
|
Response of
Interference
|
Electrostatic discharge test.
Frequency test of power
In Electromagnetic field.
Emission of radio electronic
wave filed.
|
IEC 61000-4-2 satisfied
IEC 61000-4-8 satisfied
IEC 61000-4-3 satisfied
|
|
Environmental
|
Acc.Temperature*
Acc.HuMidity*
Physical Shock Vibration*
|
-10? ~ 50? (15 ~ 22?)
40%~95%/22?
11ms, 50g satisfied
10 ~ 33Hz, 2G satisfied
|
|
Power supply
Duration time*
|
2x, 1.5V¨C¨size Alkaline
> 200 hr
|
|
Internal function
|
POST function
Display of insufficient measurement time
Display of over and under from ref. Value.
Battery status bar-gragh
Result freeze function.
Cal. Factor Adjust. In digital methode
|
|
*Satisfiled, Required ANSI N42. 17A
|
|
Radiation Safety Personel Dozimetry
|
|
Radiation Safety
Personel Dozimetry
Atomtex Personal Dosimeter / Digital;
Easy to operate, pocket-sized microprocessor instruments with high accuracy and reliability. Together with the reader connected to PC it can be a part of automated monitoring system of staff dose burden.
Features;
�Simultaneous wide-range gamma radiation dose and dose rate measuring
�Proof aginst impacts and vibrations, dust and water, electromegnetic-resistant
�Continuous self-testing of detector and cells discharge
�Audible and visual alarm
�Stand-alone or system application
�Pocket-sized and light weight
�Pulsed x-ray radiation alarming mode, pulse duration > 10 ns
Application;
�Nuclear industry
�Nuclear medicine
�Radiology
�NDT
�Emergency
�Civil aviation
�Scientific research
�Population dose burden monitoring
The dosimeters are intended to measure personal equivalent x-ray and gamma radiation dose and dose rate in the energy range from 50 keV to 1.5 MeV. The detector is GM-tube with the energy compensative filter. Microprocessor processing and proper background detection ensure high accuracy of dose measurement within the wide dose rate measuring range. The microprocessor controls operation modes over, calculates, outputs data on a backlit LCD and performs self-testing. The nonvolatile memory keeps the accumulated dose and its accumulation history when the dosimeter is off. The dosimeter is calibrated on a water phantom of 30 x 30 x 15 cm. The dosimeter is designed to be carried in a breast pocket. It complies with ISO4037-3 International standard requirements.
The dosimeter can operate singly or in a dosimetry control system: dosimeter - reader - PC. The dosimeter connects to the reader via IR channel, and the reader connects to PC via RS232. The dosimeter software is intended to:
- Read/setup personal and serial dosimeter numbers;
- Change dose and dose rate thresholds;
- Disable/enable to change dosimeter thresholds by the dosimeter button;
- Change the dose accumulation interval in the range from 1 to 255 min and evaluate accumulated dose for each time interval within a work shift;
- Save automatically up to 800 dose values in the nonvolatile memory accumulated for the selected accumulation interval;
- Reset accumulated dose;
- Disable/enable to reset accumulated dose by the dosimeter button;
- Save automatically data in the data base and print them.
The operation modes are "Dose ", "Dose rate ", "Economical", "Menu", "Reset dose", "Dose threshold", "Dose rate threshold" and "Data exchange with PC".
Item No:ENK-PDD-117
|
TECHNICAL SPESIFICATIONS
|
|
Measuring range
|
|
|
dose equivalent (in increment of 0.1 µSv)
|
|
|
AT2503, AT2503A
|
1 µSv - 10 Sv
|
|
dose equivalent rate
|
|
|
AT2503
|
0.1 µSv/h - 0.5 Sv/h
|
|
AT2503A
|
0.1 µSv/h - 0.1 Sv/h
|
|
Energy range
|
50 keV - 1.5 MeV
|
|
Intrinsic dose measurement error
|
± 15 %
|
|
Calibration error on 137Cs
|
± 5 %
|
|
Intrinsic dose rate measurement error
|
|
|
in the range from 0.1 to 1 µSv/h
|
± 25 %
|
|
more than 1 µSv/h
|
± 15 %
|
|
Energy sensitivity response
in the range from 50 keV to 1.5 MeV
|
± 30 %
|
|
Audible and visual alarm at dose and dose rate measuring range or dose and dose rate threshold exceeding; detector failure; cells discharge
|
|
|
Alarm thresholds (independent)
|
|
|
dose: 30 µSv, 200 µSv, 1 mSv, 4.2 mSv, 12.5 mSv, 50 mSv, 100 mSv, 1 Sv
|
|
|
dose rate: 0.6 µSv/h, 3 µSv/h, 30 µSv/h, 300 µSv/h, 3 mSv/h, 30 mSv/h, 300 mSv/h, 500 mSv/h
|
|
|
customized thresholds
|
|
|
Anisotropy within ±75°
|
|
|
for 137Cs and 60Co
|
± 20 %
|
|
for 241Am
|
± 50%
|
|
Response time to dose rate change when dose rate > 10 µSv/h
|
5 s
|
|
Radiation overload
|
|
|
AT2503
|
up to 5 Sv/h
|
|
AT2503A
|
up to 1 Sv/h
|
|
Operating conditions
|
|
|
operating temperature range
|
-10? - + 40?
|
|
relative humidity at + 40? ?
|
up to 98 %
|
|
shock-proof (to fall from 1.5 m)
|
|
|
Operation mode setup time
|
1 min
|
|
Protection class
|
IP54
|
|
Power requirements - 3 cells, type
|
SR44, V357, LR44, A76
|
|
Continuous operation time from one cells set
when dose rate < 1 µSv/h in economical mode (the backlighting is off)
|
5000 h
|
|
Electromagnetic compatibility
|
|
|
CEI/IEC 61000-4-2:1995)
|
|
|
IEC 61000-4-3:2002)
|
|
|
Dimensions
|
|
|
dosimeter
|
85?46?16 mm
|
|
reader
|
90?66?28 mm
|
|
Weight
|
|
|
dosimeter
|
70 g
|
|
reader
|
300 g
|
Complete set: personal dosimeter, cells, chain with a clamp, plastic boxes for easy decontamination, Manual and package. The reader and applied software and AT2503 and AT2503A modifications with the operating temperature range from-30 to +600? and the optional pulsed x-ray radiation alarming mode are supplied on additional order.
The personal dosimeters AT2503 and AT2503A have pattern approval certificates of Republic of Belarus, Russian Federation, Ukraine, Kazakhstan and Lithuania.
They comply with IEC 61283 International standard requirements. They also conform with the 89/33/EEC Directive complying with EN 55022 B:1998 and EN 55024 B: 1998 stansdard requirements. |
|
|
|
Radiation Alarm Monitor & Dosimeter
|
|
Radiation Safety
Radiation Alarm Monitor / Catch-1;
Features and Applications;
Personal radiation alarm monitor is very compact and light weight unit for operator who works in range of radiation occurrence such as nuclear plant, hospital, university, and industrial field. Alarm sound over 75dB and also red LED display signals the exposure of X-ray, ?-ray, ß-ray immediately.
Catch-1 is very light and compact (49x72.5x16mm/55g) size and can be attached to the belt, shirt pocket, apron, etc with the very rugged clip.
Power supplied by only one 1.5V battery(AAA size) and life time is about 5,000 hours.
|
TECHNICAL SPECIFICATIONS
|
|
RADIATION DETECTED
|
X-RAY AND GAMMA, HARD BETA
|
|
ENERGY RANGE
|
30KEV TO 1.25 MEV.
|
|
DETECTOR
|
G. M. TUBE
|
|
SIGNAL
|
AUDIBLE AND LED: INDECATOR LIGHT
|
|
SOUND LEVEL
|
75dB
|
|
PULSE DURATION
|
100ms
|
|
PULSE FREQUENCY
|
2,500 ~ 2,600Hz
|
|
ON-OFF SWITCH
|
NONE: IN CONSTANT STAND-BY OPERATION MODE
|
|
SENSITIVITY
(TYPICAL FOR CESIUM-137)
|
BACKGROUND: 1BLEEP PER 10 ~ 20min
1mR/h: 3 BLEEPS/min
10mR/h: 30 BLEEPS/min 1R/h AND UP CONTINUOUS TONE
|
|
OPERATING TEMPERATURE
RANGE
|
-15°C ~ 50°C
|
|
RELATIVE HUMIDITY
|
10% ~ 80%
|
|
WATER
|
RESISTANT
|
|
BATTERY TYPE
|
AAA TYPE 1.5V ONE TYPE
|
|
TYPIACAL BATTERY LIFE
|
MINIMUM 6 MONTHS WITH CONTINUOUS BACKGROUND
RADIATON FIELD: EASILY REPLACED
|
|
SIZE
|
72.5 x 16 x 49mm (2.85 x 0.63 x1.9in)
|
|
WEIGHT
|
APPROX. 55 GRAMS(1.94OZ INCLUDING BATTERIES
|
|
CASE
|
MATERIAL ABS
|
Item No:ENK-RAM-118
Radiation Safety
Pen Dosimeter
Applications;
�Portable instrument specially designed to measure your body"s total accumulated dose.
�Pen size
�A rugged pocket clip enables the device to be secured in a shirt pocket or elsewhere on the user"s garments.
�Simple to use
�Direct-reading of radiation exposure and dose
Spesifications;
�Direct gamma and x-ray dosimeter
�0-200 mR Measuring range
�Temperature Range: -20º to 50º C
�4.5 in (L) x 0.6 in (D)
(11.43 cm (L) x 1.52 cm (D))
Item No:ENK-PD-119
Dosimeter Charger
Dosimeter charger display the charging condition and easy to use and light weight.
Supplied power is only one 1.5V battery and 1000 times over charging is possible
Spesifications;
�Direct reading dosimeter charger
�Compatible with all dosimeters
�Activated by contact with dosimeter
�3.4 in (H) x 3.6 in (W) x 4.6 in (L)
(8.64 cm (H) x 9.14 cm (W) x 11.68 cm (L))
Item No:ENK-DC-120
|
|
|
|
Penatremeter & Step Wedges
|
| |
|
|
|
|
F 04
F 08
|
Item No:ENK-WPKSF-080
Item No:ENK-WPKSF-081
Item No:ENK-WPKSF-082
Stell
|
F 02
F 04
F 08
|
Item No:ENK-WPJISF-089
Item No:ENK-WPJISF-090
Item No:ENK-WPJISF-091
Stell
|
|
S 02
S 04
S 08
|
Item No:ENK-WPKSS-083
Item No:ENK-WPKSS-084
Item No:ENK-WPKSS-085
Stainless
|
S 02
S 04
S 08
|
Item No:ENK-WPJISS-092
Item No:ENK-WPJISS-093
Item No:ENK-WPJISS-094
Stainless
|
|
A 02
A 04
A 08
|
Item No:ENK-WPKSA-086
Item No:ENK-WPKSA-087
Item No:ENK-WPKSA-088
Aluminum
|
A 02
A 04
A 08
|
Item No:ENK-WPJISA-095
Item No:ENK-WPJISA-096
Item No:ENK-WPJISA-097
Aluminum
|
En Type; �13/Fe, Cu, Al(2, 5 �10mm) / Item No:ENK-ENP13-098
�10/Fe, Cu, Al(5 �20mm) / Item No:ENK-ENP10-099
�6/Fe, Cu, Al(12.5 �50mm) / Item No:ENK-ENP6-100
�1/Fe, Cu,Al(40 �160mm) / Item No:ENK-ENP1-101
Hole Type; �ASME
SET��/ 5, 7, 10, 12, 15, 17, 20, 25, 30, 35, 40, 45, 50 / Item No:ENK-ASMEPA-102
SET��/ 60, 80, 100, 120, 160, 200 / Item No:ENK-ASMEPA-103
�ASTM / 5-160 / Item No:ENK-ASMTP-104
�MIL STD-453 / .25-8.0 / Item No:ENK-MILP-105
�AFNOR (HA,HB,C,H3) / Item No:ENK-AFNP-106
#Material selection(When you purchase / Steel, AL, S/S, Cu, etc)
Step Wedges �4Step / Stell, Al, S/S / Item No:ENK-SW-107
�8Step / Stell, Al, S/S / Item No:ENK-SW-108
�16Step / Stell, Al, S/S / Item No:ENK-SW-109
Step wedges are used for the calibration of X-ray machines and evaluation of techniques.
Contrast Meter �F1 (Steel) / Item No:ENK-CM-110
�F2 (Steel) / Item No:ENK-CM-111
�D1, D2, D3, D4 (Aluminium) / Item No:ENK-CM-112
�15 type, 20 type, 25 type / Item No:ENK-CM-113
|
|
|
|
Exposure Accessories
|
|
Lead Mark & Lead Mark Case
Lead Mark;
�R-1 / Item No:ENK-LM1-059
�R-30 / Item No:ENK-LM30-060
�R-50 / Item No:ENK-LM50-061
�R-100 / Item No:ENK-LM100-062
Configuration of R-30;
1 - 0 : 30marks each
A - Z : 30marks each
Lead Mark Case;
Lead Mark Case / Item No:ENK-LMC-063
Lead Screen
Lead Alloy Intensifying Screens;
�Reduced Scattered Radiation
�Intensifies Image
�Available in rolls and all popular sheet size
Size;
�10 cm X 12 cm / Item No:ENK-LAS-064
�10 cm X 16 cm / Item No:ENK-LAS-065
�10 cm X 24 cm / Item No:ENK-LAS-066
�10 cm X 48 cm / Item No:ENK-LAS-067
�
Thickness: 0.125mm, 0.25mm, 1.0mm
Fluorescent Screen;
�Reduced Scattered Radiation
�Intensifies Image
�Available in rolls and all popular sheet size
�4 times better sensitivity than lead alloy intensifying screen
Size;
�10 cm X 12 cm / Item No:ENK-LFS-068
�10 cm X 16 cm / Item No:ENK-LFS-069
�10 cm X 24 cm / Item No:ENK-LFS-070
�10 cm X 48 cm / Item No:ENK-LFS-071
Film Casette
Plastic Type Size;
�10 cm X 12 cm / Item No:ENK-FCP-072
�10 cm X 16 cm / Item No:ENK-FCP-073
�10 cm X 24 cm / Item No:ENK-FCP-074
�10 cm X 48 cm / Item No:ENK-FCP-075
Magnetic Chuck
�MD �L type / Item No:ENK-MC-076
�MD �S type / Item No:ENK-MC-077
�MAG �S type / Item No:ENK-MC-078
�NFC� type(for non ferromagnetic) / Item No:ENK-MC-079
Holding force to attach any size film cassette to a magnetic steel surface.
|
|
|
|
Darkrooms & Equipments
|
Film Iluminators �Power: 1 ? 220V 50/60Hz 1.52A 350W
�Material: SS41 Plate
�Fluorescent Lamp: U-Type 55W 6EA
�Cooling Fan: 230V 16/14W
�Size: 605(L) X 200 (W) X 195 (H)�Unit = mm
�Illimunation View Face: Fluorescent Lamp 130.000 �150.000 Lux
�Electronic Ballast For Fluorescent Lamp 220V 50/60Hz 52W
�Weight:About 10 kg
�Switch:On/Off foot switch
Stainless Steel Item No:ENK-FI-042
Carbon Steel Item No:ENK-FI-043
Darkroom Safe Light �15 watt Lamp
�Can be mounted on a wall or hung from a ceiling
�8 in (W) X 10 in (H)
(20 cm (W) X 25 cm (H))
Item No:ENK-DSF-044
Film Hanger �10 cm X 12 cm / Item No:ENK-FH-045
�10 cm X 16 cm / Item No:ENK-FH-046
�10 cm X 24 cm / Item No:ENK-FH-047
�10 cm X 48 cm / Item No:ENK-FH-048
Darkroom Accessories Darkroom ventilator / Item No:ENK-DADV-049
Darkroom timer / Item No:ENK-DADT-050
Thermometer Item No:ENK-DATH-051
Film Storage Box / Item No:ENK-DASB-052
Film Cutter / Item No:ENK-DAFC-053
Film DensitometerPDA-100 Digital Densitometer ;
�Light Weight,Portable
�Power: AA Battery
�Accuracy: ±0.03D
�Range: 0 �4.0D
�Size : 160 x 65 x 30mm 400g
Item No:ENK-FD-054
X-Rite 301 Digital Densitometer;
�Power: AC220V/60Hz
�Accuracy: ±0.02D / 1.2mm �3mm
�Range: 0 �5.0D
�Size : 260.4 x 381 x 133.4mm
Item No:ENK-FD-055
X-Rite 331 Digital Densitometer;
Item No:ENK-FD-056
Reference Films �ASTM/E155,E186,E192,E272,E280 ,E310,E242, E390, E446
�IIW / Al. Steel
Item No:ENK-RF-057
Film Density StripItem No:ENK-FDS-058
|
|
|
|
Control Assemblies & Source Guide Tubes
|
|
Control AssembliesReel Control Assembly-KRC1;
Size:25 ft (7.5 m) / Item No:ENK-CA-005
35 ft (10.5 m) / Item No:ENK-CA-006
50 ft (15 m) / Item No:ENK-CA-007
-Pistol Control Assembly-KRC2;
Size:25 ft (7.5 m)/ Item No:ENK-CA-008
35 ft (10.5 m) / Item No:ENK-CA-009
50 ft (15 m) / Item No:ENK-CA-010
-Pistol Grip Control-KRC2 / Item No:ENK-CA-011
-Pistol Grip Control-KRC1 / Item No:ENK-CO-012
*Customs length are available for reel control assembly and pistol control assembly
Control Assembly Accessories;
1-Safety Connector / Item No:ENK-CA-013
2-Control Cable Adaptor / Item No:ENK-CA-014
3-Crank Arm Assembly / Item No:ENK-CA-015
Source Guide TubesSource Guide Tube with Fixed Stop;
Size:7 ft (2.1 m) / Item No:ENK-SG-016
-Source Guide Tube Extension;
Size:7 ft (2.1 m) / Item No:ENK-SG-017
*Customs length are available for source guide tube with fixed stop and source guide tube extension
-Source Guide Accessories;
1-Removable source stop for source guide tube /
Item No:ENK-SG-018
2-Connector for source guide tube /
Item No:ENK-SG-019
3-Fixed source stop for source guide tube /
Item No:ENK-SG-020
4- Connector for source guide tube extension /
Item No:ENK-SG-021
5- Connector for source guide tube extension /
Item No:ENK-SG-022
|
|
|
|
Collimators & Real Time Imaging System
|
Gamma-Ray Collimators
Collimators contain and direct the beam of radiation during exposure.A wide range of collimators have been developed to meet the variety of applications and techniques used.
-Collimator TSC-19 (90º),TSC-19 (120º), TSC-19P (360º);
|
|
TSC-19 (90º)
|
TSC-19 (120º)
|
TSC-19P (360º)
|
|
Shielding Material
|
Tungsten
|
Tungsten
|
Tungsten
|
|
Diameter
|
30 mm
|
30 mm
|
32 mm
|
|
Length
|
54 mm
|
54 mm
|
58 mm
|
|
Weight
|
390 gr
|
400 gr
|
360 gr
|
|
Beam Size
|
90 Conical Side Throw
|
120 Conical Side Throw
|
360º Panoramic
|
|
Attenuation
|
Ir-192:1.0x10-1 , Co-60:3.8 x 10-1
|
Ir-192:1.0x10-1 , Co-60:3.8 x 10-1
|
Ir-192:1.0x10-1 , Co-60:3.8 x 10-1
|
|
Item No
|
ENK-CO-038
|
ENK-CO-039
|
ENK-CO-040
|
Real time Imaging System
Imaging scope specifications
X-ray source : Gadolinium �153 isotope
Isotope Half life : 242days
Principle X-ray energies : 44keV and 100KeV
Power source : Two 1.5 volt ��size alkaline batteries
Image resolution : Up to 5lp/mm
Weight : 4.3kg(9.5 lbs)
License requirements : A license to possess a radioactive isotope is normally needed.
We will assist you if required.
Item No:ENK-RI-041
|
|
|
|
|
|
|
|
|
| Bize Ulaşın | | Adres | : | Kuzey Sahil Yolu Lodos Sok.No:9 Güzelyalı-Pendik/İstanbul | | Telefon | : | +90 216 494 12 32 - 493 25 03 - 493 99 77 | | Faks | : | +90 216 493 99 81 | | E-mail | : | enkon@enkon.com.tr | |
|
| | | | Ürünlerimiz | |
|